Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
1.
Biosens Bioelectron ; 255: 116219, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38552525

RESUMO

We introduce a versatile method to convert NAD+ or NADP+ -dependent dehydrogenases into quasi-direct electron transfer (quasi-DET)-type dehydrogenases, by modifying with a mediator on the enzyme surface toward the development of 2.5th generation enzymatic sensors. In this study, we use ß-hydroxybutyrate (BHB) dehydrogenase (BHBDh) from Alcaligenes faecalis (AfBHBDh) as a representative NAD+ or NADP+ -dependent dehydrogenase. BHBDhs are important in ketone monitoring, especially for the diagnosis of diabetic ketoacidosis. We modified AfBHBDh with a thiol-reactive phenazine ethosulfate (trPES). We designed, constructed, and modified mutant BHBDhs harboring cysteine residues within 20 Å from the C4 nicotinamide in NAD+/NADH. Mutants Ser65Cys, Thr96Cys, and Lys106Cys showed indistinguishable catalytic activities from the wild-type enzyme, even after trPES modification. These trPES-modified mutants were immobilized on gold disk electrodes via amine coupling with succinimide-groups of dithiobis (succinimidyl hexanoate) self-assembled monolayers for electrochemical measurements. Considering there is a wide range of BHB concentrations, we exploited the linear regression in log scales. The linear range for the sensors with trPES-modified BHBDh mutants Ser65Cys, Thr96Cys, and Lys106Cys were 0.1-4.0 mM in both buffer solution and artificial interstitial fluid (ISF). They have limits of detection of 0.047 mM for Ser65Cys, 0.15 mM for Thr96Cys, and 0.060 mM for Lys106Cys in buffer solution, and 0.12 mM, 0.089 mM, and 0.044 mM in artificial ISF, respectively. These results indicate that redox mediator modification of NAD(P)-dependent dehydrogenases converts them into quasi-DET-type dehydrogenases, thereby enabling their utilization in 2.5th generation enzymatic sensors, which will facilitate the construction of enzymatic sensors suitable for continuous monitoring systems.


Assuntos
Técnicas Biossensoriais , Glucose , NAD , Elétrons , NADP , Técnicas Biossensoriais/métodos , Oxirredutases
2.
Biosens Bioelectron ; 254: 116197, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38493528

RESUMO

Herein, we present a proof-of-concept of an enzyme sensor combining closed bipolar electrode system with quasi-direct electron transfer (DET) type enzyme. The closed bipolar electrode system was tested using cyclic voltammetry, with L-lactate as a model substrate. L-Lactate was detected through measurement of the change in junction potential across the bipolar electrode. This change in junction potential was caused by reduction of amino reactive phenazine ethosulfate conjugated to Aerococcus vilidans derived engineered L-lactate oxidase (AvLOx) which shows a quasi-DET signal. Using the closed bipolar electrode system allowed simultaneous measuring using cyclic voltammetry and open circuit potential (OCP) and achieved a limit of detection of 400 µM and 76.2 µM lactate respectively. The sensor was then demonstrated to perform with equivalent sensitivity using OCP across varying surface areas. To the best of our knowledge this is the first time a closed bipolar electrode system has been used with an enzyme which is capable of quasi-direct or direct electron transfer. This work can be expanded further to other enzymes capable of directly altering the junction potential of an electrode surface.


Assuntos
Técnicas Biossensoriais , Elétrons , Enzimas Imobilizadas , Compostos Orgânicos , Eletrodos , Lactatos
3.
Int J Mol Sci ; 25(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38474105

RESUMO

Although IgG-free immunosensors are in high demand owing to ethical concerns, the development of convenient immunosensors that alternatively integrate recombinantly produced antibody fragments, such as single-chain variable fragments (scFvs), remains challenging. The low affinity of antibody fragments, unlike IgG, caused by monovalent binding to targets often leads to decreased sensitivity. We improved the affinity owing to the bivalent effect by fabricating a bivalent antibody-enzyme complex (AEC) composed of two scFvs and a single glucose dehydrogenase, and developed a rapid and convenient scFv-employed electrochemical detection system for the C-reactive protein (CRP), which is a homopentameric protein biomarker of systemic inflammation. The development of a point-of-care testing (POCT) system is highly desirable; however, no scFv-based CRP-POCT immunosensors have been developed. As expected, the bivalent AEC showed higher affinity than the single scFv and contributed to the high sensitivity of CRP detection. The electrochemical CRP detection using scFv-immobilized magnetic beads and the bivalent AEC as capture and detection antibodies, respectively, was achieved in 20 min without washing steps in human serum and the linear range was 1-10 nM with the limit of detection of 2.9 nM, which has potential to meet the criteria required for POCT application in rapidity, convenience, and hand-held detection devices without employing IgGs.


Assuntos
Técnicas Biossensoriais , Anticorpos de Cadeia Única , Humanos , Anticorpos de Cadeia Única/metabolismo , Proteína C-Reativa , Imunoensaio
4.
Biosens Bioelectron ; 251: 116118, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38382273

RESUMO

Glycated albumin (GA), defined as the percentage of serum albumin glycation, is a mid-term glycemic control marker for diabetes. The concentrations of both glycated human serum albumin (GHSA) and total human serum albumin (HSA) are required to calculate GA. Here, we report the development of a GA sensor employing two albumin aptamers: anti-GHSA aptamer which is specific to GHSA and anti-HSA aptamer which recognizes both glycated and non-glycated HSA. We combine these aptamers with extended gate field effect transistors (EGFETs) to realize GA monitoring without the need to pretreat serum samples, and therefore suitable for point of care and home-testing applications. Using anti-GHSA aptamer-immobilized electrodes and EGFETs, we measured GHSA concentrations between 0.1-10 µM within 20 min. The sensor was able to measure GHSA concentration in the presence of BSA for a range of known GA levels (5-29%). With anti-HSA aptamer-immobilized electrodes and EGFETs, we measured total HSA concentrations from 1-17 µM. Furthermore, GHSA and total HSA concentrations of both healthy and diabetic-level samples were determined with GHSA and HSA sensors. The measured GHSA and total HSA concentrations in three samples were used to determine respective GA percentages, and our calculations agreed with GA levels determined by reference methods. Thus, we developed simple and rapid dual aptamer-based EGFET sensors to monitor GA through measuring GHSA and total HSA concentration, without the need for sample pretreatment, a mandatory step in the current standard of enzymatic GA monitoring.


Assuntos
Técnicas Biossensoriais , Diabetes Mellitus , Humanos , Albumina Sérica Glicada , Produtos Finais de Glicação Avançada , Albumina Sérica , Albumina Sérica Humana , Oligonucleotídeos
5.
Annu Rev Biomed Eng ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424090

RESUMO

Among the various types of enzyme-based biosensors, sensors utilizing enzymes capable of direct electron transfer (DET) are recognized as the most ideal. However, only a limited number of redox enzymes are capable of DET with electrodes, that is, dehydrogenases harboring a subunit or domain that functions specifically to accept electrons from the redox cofactor of the catalytic site and transfer the electrons to the external electron acceptor. Such subunits or domains act as built-in mediators for electron transfer between enzymes and electrodes; consequently, such enzymes enable direct electron transfer to electrodes and are designated as DET-type enzymes. DET-type enzymes fall into several categories, including redox cofactors of catalytic reactions, built-in mediators for DET with electrodes and by their protein hierarchic structures, DET-type oxidoreductases with oligomeric structures harboring electron transfer subunits, and monomeric DET-type oxidoreductases harboring electron transfer domains. In this review, we cover the science of DET-type oxidoreductases and their biomedical applications. First, we introduce the structural biology and current understanding of DET-type enzyme reactions. Next, we describe recent technological developments based on DET-type enzymes for biomedical applications, such as biosensors and biochemical energy harvesting for self-powered medical devices. Finally, after discussing how to further engineer and create DET-type enzymes, we address the future prospects for DET-type enzymes in biomedical engineering. Expected final online publication date for the Annual Review of Biomedical Engineering, Volume 26 is May 2024. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.

6.
Biosens Bioelectron ; 252: 116092, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401283

RESUMO

This work presents the development of an enzyme fuel cell, termed "BioBattery", that utilizes multicopper oxidases as the anodic enzyme in a non-diffusion limited system. We evaluated various enzyme variants as the anode, including multicopper oxidase from Pyrobaculum aerophilum, laccase from Trametes versicolor, and bilirubin oxidase from Myrothecium verrucaria. Several combinations of cathodes were also examined, focusing on the reduction of oxygen as the primary electron acceptor. The optimal pairing used multicopper oxidase from Pyrobaculum aerophilum as the anode and amine reactive phenazine ethosulfate modified bovine serum albumin as the cathode. BioBattery was integrated with our previously developed BioCapacitor, proving capable of consistently powering a 470 µF capacitor, positioning it as a modular power source for wearable and implantable systems. This research work addresses and overcomes some of the fundamental limitations seen in enzyme fuel cells, where power and current are often limited by substrate accessibility to the active electrode surface. (152 words).


Assuntos
Fontes de Energia Bioelétrica , Técnicas Biossensoriais , Trametes , Lacase , Eletrodos
7.
Anal Chem ; 96(10): 4076-4085, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38408165

RESUMO

In this work, direct electron transfer (DET)-type extended gate field effect transistor (EGFET) enzymatic sensors were developed by employing DET-type or quasi-DET-type enzymes to detect glucose or lactate in both 100 mM potassium phosphate buffer and artificial sweat. The system employed either a DET-type glucose dehydrogenase or a quasi-DET-type lactate oxidase, the latter of which was a mutant enzyme with suppressed oxidase activity and modified with amine-reactive phenazine ethosulfate. These enzymes were immobilized on the extended gate electrodes. Changes in the measured transistor drain current (ID) resulting from changes to the working electrode junction potential (φ) were observed as glucose and lactate concentrations were varied. Calibration curves were generated for both absolute measured ID and ΔID (normalized to a blank solution containing no substrate) to account for variations in enzyme immobilization and conjugation to the mediator and variations in reference electrode potential. This work resulted in a limit of detection of 53.9 µM (based on ID) for glucose and 2.12 mM (based on ID) for lactate, respectively. The DET-type and Quasi-DET-type EGFET enzymatic sensor was then modeled using the case of the lactate sensor as an equivalent circuit to validate the principle of sensor operation being driven through OCP changes caused by the substrate-enzyme interaction. The model showed slight deviation from collected empirical data with 7.3% error for the slope and 8.6% error for the y-intercept.


Assuntos
Técnicas Biossensoriais , Elétrons , Técnicas Biossensoriais/métodos , Glucose/metabolismo , Glucose 1-Desidrogenase/metabolismo , Ácido Láctico , Enzimas Imobilizadas/metabolismo , Eletrodos
8.
J Am Chem Soc ; 146(6): 4087-4097, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38295327

RESUMO

DNA-protein complexes are attractive components with broad applications in various research fields, such as DNA aptamer-enzyme complexes as biosensing elements. However, noncovalent DNA-protein complexes often decrease detection sensitivity because they are highly susceptible to environmental conditions. In this study, we developed a versatile DNA-protein covalent-linking patch (D-Pclip) for fabricating covalent and stoichiometric DNA-protein complexes. We comprehensively explored the database to determine the DNA-binding ability of the candidates and selected UdgX as the only uracil-DNA glycosylase known to form covalent bonds with DNA via uracil, with a binding efficiency >90%. We integrated a SpyTag/SpyCatcher protein-coupling system into UdgX to create a universal and convenient D-Pclip. The usability of D-Pclip was shown by preparing a stoichiometric model complex of a hemoglobin (Hb)-binding aptamer and glucose oxidase (GOx) by mixing at 4 °C. The prepared aptamer-GOx complexes detected Hb in a dose-dependent manner within the clinically required detection range in buffer and human serum without any washing procedures. D-Pclip covalently connects any uracil-inserted DNA sequence and any SpyCatcher-fused protein stoichiometrically; therefore, it has a high potential for various applications.


Assuntos
Proteínas de Ligação a DNA , DNA , Humanos , Proteínas de Ligação a DNA/química , DNA/química , Sequência de Bases , Uracila
9.
Biosens Bioelectron ; 250: 116049, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38290381

RESUMO

Contemporary electrochemical impedance spectroscopy (EIS)-based biosensors face limitations in their applicability for in vivo measurements, primarily due to the necessity of using a redox probe capable of undergoing oxidation and reduction reactions in solution. Although previous investigations have demonstrated the effectiveness of EIS-based biosensors in detecting various target analytes using potassium ferricyanide as a redox probe, its unsuitability for blood or serum measurements, attributed to its inherent toxicity, poses a significant challenge. In response to this challenge, our study adopted a unique approach, focusing on the use of ingestible materials, by exploring naturally occurring substances within the body, with a specific emphasis on pyrroloquinoline quinone (PQQ). Following an assessment of PQQ's electrochemical attributes, we conducted a comprehensive series of EIS measurements. This involved the thorough characterization of the sensor's evolution, starting from the bare electrode and progressing to the immobilization of antibodies. The sensor's performance was then evaluated through the quantification of insulin concentrations ranging from 1 pM to 100 nM. A single frequency was identified for insulin measurements, offering a pathway for potential in vivo applications by combining PQQ as a redox probe with EIS measurements. This innovative approach holds promise for advancing the field of in vivo biosensing based on the EIS method.


Assuntos
Técnicas Biossensoriais , Cofator PQQ , Técnicas Biossensoriais/métodos , Insulina , Espectroscopia Dielétrica , Imunoensaio , Oxirredução , Eletrodos
10.
Int J Mol Sci ; 24(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36982354

RESUMO

Therapeutic monoclonal antibodies (mAbs) are currently the most effective medicines for a wide range of diseases. Therefore, it is expected that easy and rapid measurement of mAbs will be required to improve their efficacy. Here, we report an anti-idiotype aptamer-based electrochemical sensor for a humanized therapeutic antibody, bevacizumab, based on square wave voltammetry (SWV). With this measurement procedure, we were able to monitor the target mAb within 30 min by employing the anti-idiotype bivalent aptamer modified with a redox probe. A fabricated bevacizumab sensor achieved detection of bevacizumab from 1-100 nM while eliminating the need for free redox probes in the solution. The feasibility of monitoring biological samples was also demonstrated by detecting bevacizumab in the diluted artificial serum, and the fabricated sensor succeeded in detecting the target covering the physiologically relevant concentration range of bevacizumab. Our sensor contributes to ongoing efforts towards therapeutic mAbs monitoring by investigating their pharmacokinetics and improving their treatment efficacy.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Bevacizumab , Aptâmeros de Nucleotídeos/metabolismo , Anticorpos Monoclonais , Oxirredução , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos
11.
Int J Mol Sci ; 24(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36768169

RESUMO

The electrochemical enzyme sensors based on direct electron transfer (DET)-type oxidoreductase-based enzymes are ideal for continuous and in vivo monitoring. However, the number and types of DET-type oxidoreductases are limited. The aim of this research is the development of a versatile method to create a DET-type oxidoreductase complex based on the SpyCatcher/SpyTag technique by preparing SpyCatcher-fused heme c and SpyTag-fused non-DET-type oxidoreductases, and by the in vitro formation of DET-type oxidoreductase complexes. A heme c containing an electron transfer protein derived from Rhizobium radiobacter (CYTc) was selected to prepare SpyCatcher-fused heme c. Three non-DET-type oxidoreductases were selected as candidates for the SpyTag-fused enzyme: fungi-derived flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenase (GDH), an engineered FAD-dependent d-amino acid oxidase (DAAOx), and an engineered FMN-dependent l-lactate oxidase (LOx). CYTc-SpyCatcher (CYTc-SC) and SpyTag-Enzymes (ST-GDH, ST-DAAOx, ST-LOx) were prepared as soluble molecules while maintaining their redox properties and catalytic activities, respectively. CYTc-SC/ST-Enzyme complexes were formed by mixing CYTc-SpyCatcher and SpyTag-Enzymes, and the complexes retained their original enzymatic activity. Remarkably, the heme domain served as an electron acceptor from complexed enzymes by intramolecular electron transfer; consequently, all constructed CYTc-SC/ST-Enzyme complexes showed DET ability to the electrode, demonstrating the versatility of this method.


Assuntos
Elétrons , Flavina-Adenina Dinucleotídeo , Flavina-Adenina Dinucleotídeo/metabolismo , Glucose 1-Desidrogenase/metabolismo , Proteínas/metabolismo , Oxirredução
12.
Commun Biol ; 5(1): 1334, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36473944

RESUMO

The heterotrimeric flavin adenine dinucleotide dependent glucose dehydrogenase is a promising enzyme for direct electron transfer (DET) principle-based glucose sensors within continuous glucose monitoring systems. We elucidate the structure of the subunit interface of this enzyme by preparing heterotrimer complex protein crystals grown under a space microgravity environment. Based on the proposed structure, we introduce inter-subunit disulfide bonds between the small and electron transfer subunits (5 pairs), as well as the catalytic and the electron transfer subunits (9 pairs). Without compromising the enzyme's catalytic efficiency, a mutant enzyme harboring Pro205Cys in the catalytic subunit, Asp383Cys and Tyr349Cys in the electron transfer subunit, and Lys155Cys in the small subunit, is determined to be the most stable of the variants. The developed engineered enzyme demonstrate a higher catalytic activity and DET ability than the wild type. This mutant retains its full activity below 70 °C as well as after incubation at 75 °C for 15 min - much higher temperatures than the current gold standard enzyme, glucose oxidase, is capable of withstanding.


Assuntos
Automonitorização da Glicemia , Glucose 1-Desidrogenase , Elétrons , Glicemia
13.
Protein Sci ; 31(10): e4434, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36173159

RESUMO

l-Lactate oxidase (LOx) is a flavin mononucleotide (FMN)-dependent triose phosphate isomerase (TIM) barrel fold enzyme that catalyzes the oxidation of l-lactate using oxygen as a primary electron acceptor. Although reductive half-reaction mechanism of LOx has been studied by structure-based kinetic studies, oxidative half-reaction and substrate/product-inhibition mechanisms were yet to be elucidated. In this study, the structure and enzymatic properties of wild-type and mutant LOxs from Enterococcus hirae (EhLOx) were investigated. EhLOx structure showed the common TIM-barrel fold with flexible loop region. Noteworthy observations were that the EhLOx crystal structures prepared by co-crystallization with product, pyruvate, revealed the complex structures with "d-lactate form ligand," which was covalently bonded with a Tyr211 side chain. This observation provided direct evidence to suggest the product-inhibition mode of EhLOx. Moreover, this structure also revealed a flip motion of Met207 side chain, which is located on the flexible loop region as well as Tyr211. Through a saturation mutagenesis study of Met207, one of the mutants Met207Leu showed the drastically decreased oxidase activity but maintained dye-mediated dehydrogenase activity. The structure analysis of EhLOx Met207Leu revealed the absence of flipping in the vicinity of FMN, unlike the wild-type Met207 side chain. Together with the simulation of the oxygen-accessible channel prediction, Met207 may play as an oxygen gatekeeper residue, which contributes oxygen uptake from external enzyme to FMN. Three clades of LOxs are proposed based on the difference of the Met207 position and they have different oxygen migration pathway from external enzyme to active center FMN.


Assuntos
Streptococcus faecium ATCC 9790 , Mononucleotídeo de Flavina , Domínio Catalítico , Streptococcus faecium ATCC 9790/metabolismo , Mononucleotídeo de Flavina/química , Cinética , Lactatos , Ligantes , Oxigenases de Função Mista/química , Oxigênio , Ácido Pirúvico , Triose-Fosfato Isomerase/metabolismo
14.
J Diabetes Sci Technol ; 16(5): 1107-1113, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35466718

RESUMO

BACKGROUND: While continuous glucose monitoring (CGM) systems allow precise and real-time blood glucose control, current electrochemicalbased CGM technologies inherently harbor enzyme instability issues. The direct electron transfer (DET) type open circuit potential (OCP) based enzyme sensing principle can minimize the catalytic turnover of the enzyme reaction, thereby providing longer-term operational stability in future CGM glucose sensors. METHOD: DET-type OCP based glucose sensors were constructed using gold disk electrodes with glucose dehydrogenase capable of DET which was immobilized using a self-assembled monolayer (SAM). The single enzyme layer prepared on the gold electrode was operated in the presence of glucose, using in vitro buffer solution, continuously for over 3 months with the OCP sensor signal monitored every 10 seconds at 25°C. RESULTS: The DET-type OCP glucose sensor was continuously operated for more than 3 months without a significant decrease of the sensor signal and sensitivity (slope). These results suggest that the DET-type OCP glucose sensor is far more stable than the sensor constructed based on the amperometric principle. The long-term stability of DET-type OCP glucose sensor is attributed to the enzyme's minimized catalytic reaction during the operation, thereby extending the lifetime of enzyme. CONCLUSION: The DET-type OCP glucose sensor can be continuously operated for more than 3 months at 25 °C, in vitro without significant decreases in sensor signal and sensitivity. While the further investigation will be required for in vivo validation, the DET-type OCP glucose sensor is ideal for next generation CGM's, especially in long duration implantable use cases.


Assuntos
Técnicas Biossensoriais , Automonitorização da Glicemia , Humanos , Técnicas Biossensoriais/métodos , Glicemia , Eletrodos , Elétrons , Flavina-Adenina Dinucleotídeo , Glucose , Ouro
15.
Biosens Bioelectron ; 208: 114232, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35390718

RESUMO

Year over year, the incidence of traumatic brain injury (TBI) in the population is dramatically increasing; thus, timely diagnosis is crucial for improving patient outcomes in the clinic. Ubiquitin C-terminal hydrolase L1 (UCH-L1), a blood-based biomarker, has been approved by the FDA as a promising quantitative indicator of mild TBI that arises in blood serum shortly after injury. Current gold standard techniques for its quantitation are time-consuming and require specific laboratory equipment. Hence, development of a hand-held device is an attractive alternative. In this study, we report a novel system for rapid, one-step electrochemical UCH-L1 detection. Electrodes were functionalized with anti-UCH-L1 antibody, which was used as a molecular recognition element for selective sensing of UCH-L1. Electrochemical impedance spectroscopy (EIS) was used as a transduction method to quantify its binding. When the electrode was incubated with different concentrations of UCH-L1, impedance signal increased against a concentration gradient with high logarithmic correlation. Upon single-frequency analysis, a second calibration curve with greater signal to noise was obtained, which was used to distinguish physiologically relevant concentrations of UCH-L1. Notably, our system could detect UCH-L1 within 5 min, without a washing step nor bound/free separation, and had resolution across concentrations ranging from 1 pM to 1000 pM within an artificial serum sample. These attributes, together with the miniaturization potential afforded by an impedimetric sensing platform, make this platform an attractive candidate for scale-up as a device for rapid, on-site detection of TBI. These findings may aid in the future development of sensing systems for quantitative TBI detection.


Assuntos
Técnicas Biossensoriais , Lesões Encefálicas Traumáticas , Biomarcadores , Lesões Encefálicas Traumáticas/diagnóstico , Espectroscopia Dielétrica , Humanos , Ubiquitina Tiolesterase
16.
Sensors (Basel) ; 22(5)2022 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35270906

RESUMO

Electrochemical aptamer-based biosensors (E-ABs) are attractive candidates for use in biomarker detection systems due to their sensitivity, rapid response, and design flexibility. There are only several redox probes that were employed previously for this application, and a combination of redox probes affords some advantages in target detection. Thus, it would be advantageous to study new redox probes in an E-AB system. In this study, we report the use of amine-reactive phenazine ethosulfate (arPES) for E-AB through its conjugation to the terminus of thrombin-binding aptamer. The constructed E-AB can detect thrombin by square-wave voltammetry (SWV), showing peak current at -0.15 V vs. Ag/AgCl at pH 7, which differs from redox probes used previously for E-ABs. We also compared the characteristics of PES as a redox probe for E-AB to methylene blue (MB), which is widely used. arPES showed stable signal at physiological pH. Moreover, the pH profile of arPES modified thrombin-binding aptamer revealed the potential application of arPES for a simultaneous multianalyte detection system. This could be achieved using different aptamers with several redox probes in tandem that harbor various electrochemical peak potentials. Our findings present a great opportunity to improve the current standard of biological fluid monitoring using E-AB.


Assuntos
Aminas , Técnicas Biossensoriais , Eletroquímica , Oxirredução , Fenazinas
17.
Biosens Bioelectron ; 203: 114027, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35114463

RESUMO

Therapeutic monoclonal antibodies (mAbs) are successful biomedicines; however, evaluation of their pharmacokinetics and pharmacodynamics demands highly specific discrimination from human immunoglobulin G naturally present in the blood. Here, we developed a novel anti-idiotype aptamer (termed A14#1) with extraordinary specificity against the anti-vascular endothelial growth factor therapeutic mAb, bevacizumab. Structural analysis of the antibody-aptamer complex showed that several bases of A14#1 recognized only the complementarity determining region (CDR) of bevacizumab, thereby contributing to its extraordinary specificity. As the CDR of bevacizumab is predicted to be highly positively charged under mildly acidic conditions and that DNA is negatively charged, the affinity of A14#1 to bevacizumab markedly increased at pH 4.7 (KD = 44 pM) than at pH 7.4 (KD = 12 nM). A14#1-based electrochemical detection method capable of detecting 31 pM of bevacizumab at pH 4.7 was thus developed. A14#1 could be potentially useful for therapeutic drug measurement as a novel ligand of bevacizumab.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Anticorpos Monoclonais , Afinidade de Anticorpos , Aptâmeros de Nucleotídeos/química , Regiões Determinantes de Complementaridade/química , Regiões Determinantes de Complementaridade/genética , Humanos , Concentração de Íons de Hidrogênio
18.
Microb Cell Fact ; 21(1): 7, 2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-34991586

RESUMO

BACKGROUND: Cyanobacteria are engineered via heterologous biosynthetic pathways to produce value-added chemicals via photosynthesis. Various chemicals have been successfully produced in engineered cyanobacteria. Chemical inducer-dependent promoters are used to induce the expression of target biosynthetic pathway genes. A chemical inducer is not ideal for large-scale reactions owing to its high cost; therefore, it is important to develop scaling-up methods to avoid their use. In this study, we designed a green light-inducible alcohol production system using the CcaS/CcaR green light gene expression system in the cyanobacterium Synechocystis sp. PCC 6803 (PCC 6803). RESULTS: To establish the green light-inducible production of isobutanol and 3-methyl-1-butanol (3MB) in PCC 6803, keto-acid decarboxylase (kdc) and alcohol dehydrogenase (adh) were expressed under the control of the CcaS/CcaR system. Increases in the transcription level were induced by irradiation with red and green light without severe effects on host cell growth. We found that the production of isobutanol and 3MB from carbon dioxide (CO2) was induced under red and green light illumination and was substantially repressed under red light illumination alone. Finally, production titers of isobutanol and 3MB reached 238 mg L-1 and 75 mg L-1, respectively, in 5 days under red and green light illumination, and these values are comparable to those reported in previous studies using chemical inducers. CONCLUSION: A green light-induced alcohol production system was successfully integrated into cyanobacteria to produce value-added chemicals without using expensive chemical inducers. The green light-regulated production of isobutanol and 3MB from CO2 is eco-friendly and cost-effective. This study demonstrates that light regulation is a potential tool for producing chemicals and increases the feasibility of cyanobacterial bioprocesses.


Assuntos
Butanóis/metabolismo , Engenharia Metabólica , Pentanóis/metabolismo , Synechocystis/genética , Synechocystis/metabolismo , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Luz , Fotorreceptores Microbianos/genética , Fotorreceptores Microbianos/metabolismo , Fotossíntese , Regiões Promotoras Genéticas , Synechocystis/crescimento & desenvolvimento
19.
J Diabetes Sci Technol ; 16(5): 1101-1106, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34986665

RESUMO

BACKGROUND: The bacterial derived flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenase (FADGDH) is the most promising enzyme for the third-generation principle-based enzyme sensor for continuous glucose monitoring (CGM). Due to the ability of the enzyme to transfer electrons directly to the electrode, recognized as direct electron transfer (DET)-type FADGDH, although no investigation has been reported about DET-type FADGDH employed on a miniaturized integrated electrode. METHODS: The miniaturized integrated electrode was formed by sputtering gold (Au) onto a flexible film with 0.1 mm in thickness and divided into 3 parts. After an insulation layer was laminated, 3 openings for a working electrode, a counter electrode and a reference electrode were formed by dry etching. A reagent mix containing 1.2 × 10-4 Unit of DET-type FADGDH and carbon particles was deposited. The long-term stability of sensor was evaluated by continuous operation, and its performance was also evaluated in the presence of acetaminophen and the change in oxygen partial pressure (pO2) level. RESULTS: The amperometric response of the sensor showed a linear response to glucose concentration up to 500 mg/dL without significant change of the response over an 11-day continuous measurement. Moreover, the effect of acetaminophen and pO2 on the response were negligible. CONCLUSIONS: These results indicate the superb potential of the DET-type FADGDH-based sensor with the combination of a miniaturized integrated electrode. Thus, the described miniaturized DET-type glucose sensor for CGM will be a promising tool for effective glycemic control. This will be further investigated using an in vivo study.


Assuntos
Técnicas Biossensoriais , Elétrons , Humanos , Acetaminofen , Técnicas Biossensoriais/métodos , Glicemia , Automonitorização da Glicemia/métodos , Eletrodos , Glucose , Glucose 1-Desidrogenase
20.
Biosens Bioelectron ; 200: 113927, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34995837

RESUMO

d-Serine biosensing has been extensively reported based on enzyme sensors using flavin adenine dinucleotide (FAD) -dependent d-amino acid oxidase (DAAOx), based on the monitoring of hydrogen peroxide generated by the enzymatic reaction, which is affected by dissolved oxygen concentration in the measurement environment in in vivo use. Here we report a novel sensing principle for d-serine, transient potentiometry based d-serine sensor using engineered DAAOx showing quasi-direct electron transfer (DET) property. DAAOx Gly52Val mutant, revealed to possess dye-mediated dehydrogenase activity using artificial synthetic electron acceptors, while its oxidase activity was negligible. The enzyme was immobilized on electrode and was modified with amine-reactive phenazine ethosulfate, resulted an enzyme electrode showing quasi-DET type response. Although OCP based monitoring took more than several minutes to obtain steady state OCP value, the time dependent OCP change monitoring, transient potentiometry, provided rapid and sensitive sensor signals. While dOCP/dt based monitoring was suitable for sensing with longer than 5 s time resolution with d-serine concentration range between 0.5 mM and 5 mM, dOCP/d t based monitoring is suitable for d-serine monitoring with much shorter time resolution (less than 1 s) with high sensitivity with wider dynamic range (20 µM-30 mM). The maximum dOCP/d t was -39.2 ± 2.0 mV/s1/2, the Km(app) was 1.9 mM, and the lower limit of detection was 20 µM. In addition, d-serine monitoring was also possible in the artificial cerebrospinal fluid. The transient potentiometry based sensing reported in this study will be further utilized to realize miniaturized, continuous, real-time, in vivo sensor for d-serine monitoring.


Assuntos
Técnicas Biossensoriais , Elétrons , Flavina-Adenina Dinucleotídeo , Glucose , Glucose 1-Desidrogenase , Potenciometria , Serina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...